Por favor, use este identificador para citar o enlazar este ítem: http://cicese.repositorioinstitucional.mx/jspui/handle/1007/3118
Fluorescencia natural y productividad primaria en el Pacífico mexicano
Ernesto García Mendoza
Helmut Maske Rubach
Acceso Abierto
Atribución
Productividad en Biología,Fluorescencia,Ciencias del mar
Se presenta la comparación entre la fluorescencia de la clorofila α estimulada por la luz de sol (fluorescencia natural; F∫), medida mediante un sensor de radiancia ascendente (Lu) y productividad primaria (Fc) determinada por Ja incorporación de 14C in situ, en aguas del Pacifico Mexicano, particularmente en la Corriente de California (cerca de la Bahía de Todos Santos) y Cuenca Delfín (parte norte del Golfo de California) en 9 y 8 muestreos respectivamente para el período de abril de 1992 a enero de 1994, además del Golfo de California durante el mes de abril de 1992 (crucero MOCE2). Se realizaron algunas pruebas que nos indicaron la variabilidad y precisión de los métodos utilizados. Para el método de incorporación de 14C. Al utilizar filtros de fibra de vidrio (GF/F) para la recolección del material particulado después de la incubación se obtuvo una Fc aproximadamente 6% mayor que con filtros de membrana de acetato de celulosa (GN-6), debido probablemente a la adsorción de material orgánico disuelto por los filtros GF/F, que se produce por exudación del fitoplancton o debido al probable rompimiento de las células durante la filtración, en general el método de medición de Fc. mediante 14C presenta una precisión de un 10% aproximadamente, con la mayor variabilidad en el manejo de las muestras. Con respecto al método de medición de Fc se determinó la estimación cuantitativa de la atenuación de la señal de fluorescencia (aF) desde su origen al sensor, en base a la descripción del espectro de la emisión de la fluorescencia de la clorofila a, así como al de la absorción debido al agua y coeficiente específico de la absorción de la clorofila a en la banda de emisión de la Fc, se obtuvo un valor de la atenuación de la señal de fluorescencia de aF∫ = 0.709 + 0.019Cla. También se determinó la profundidad abajo del sensor donde se está originando la señal de fluorescencia mediante simulaciones numéricas considerando diferentes comportamientos de la concentración de clorofila α (Cla), se obtuvo que existía un 20% de cambio de la profundidad en la cual se origina el 50%de la señal integrada (0.8 m, Cla constante) al aumentar o disminuir la Cla con la profundidad. Se determinó asimismo, hasta que profundidad existía una contribución significativa de la dispersión hacia atrás de la luz de sol Lub, mediante el uso de una placa difusora de teflón colocada abajo del sensor de Lu, a los 6m se obtuvo una contribución de Lub, a la señal de Lu, de aproximadamente un 5% y a
Solar stimulated fluorescence of chlorophyll a (natural fluorescence, Ff), measured with an upwelling radiance (Lu,) sensor, and primary productivity (Fc), measured by short-term in situ 14C incorporation, were compared in Mexican Pacific Waters. Samples were taken at stations in the California Current (near Todos Santos bay, 9 time points), in the Cuenca Delfin (northern part of California Gulf, 8 time points), between April 1992 and January 1994 and during a cruise in the Gulf of California, April 1992. The precision and accuracy of the methods were investigated: The effect of metal contamination on “C incorporation by comparison of samples with and without EDTA addition. No significant differences (0.2<P<0.5) between these treatments were found. The use of inorganic glass fiber filters. (GF/F) in comparison with polycarbonatefilters, the results of the 14C method showed 6% higher incorporation with the former. The higher values are due to adsorption of disolved organic material produced by phytoplankton onto the GF/F filters surface. The coefficient of variation of the 14C method is estimated to be 10%. The attenuation of the fluorescence emission on its path toward the sensor was calculated for the optical band width of the upwelling radiance sensor from the spectra of fluorescence emission, water absorption and specific chlorophyll a absorption. The calculation yielded an attenuation of the fluorescence emission: aFf. = 0.709 + 0.019 Cla, Cla: chlorophyll concentration. The depth below the sensor wheré the natural fluorescence received by the sensor originates was determined by numerical simulations. The depth interval below the sensor above which 50% of the measured Lu, originated was found to be 0.8 m for constant vertical Cla. This depth interval changed only 20% in the case when Cla increased or decreased with depth. A Teflon diffuser 0.3m beneath the Lu, sensor was used to estimate the amountofelastically backscatter light and the depth at which the backscattered sunlight L,contributes significantly to the Lu signal. The results shows that above 6 m the contribution of Lub, is more than 5% of the received Lu, signal in mesotrophic waters. A comparison of Fc, and Ff yields a correlation coefficient of 0.8. Both parameters do not show a linear relationship because the ratio of the quantum yield photosynthesis to fluorescence (φc/φ∫) changes with in situ irradiance. This change is due to a change of quantum yield of carbon assimilation (φc). If the
CICESE
1994
Tesis de maestría
Español
García Mendoza, E. 1994.Fluorescencia natural y productividad primaria en el Pacífico mexicano. Tesis de Maestría en Ciencias. Centro de Investigación Científica y de Educación Superior de Ensenada, Baja California. 128 pp..
PECES Y FAUNA SILVESTRE
Aparece en las colecciones: Tesis - Ecología Marina

Cargar archivos:


Fichero Tamaño Formato  
102991.pdf25.96 MBAdobe PDFVisualizar/Abrir