El presente trabajo de tesis comprende un estudio teórico experimental de un transductor de temperatura de óptica integrada tipo Fabry-Perot que opera en el modo de transmisión. El transductor consiste de una guía de onda angosta de indice de gradiente y de dos espejos dieléctricos semirreflectores en las caras de entrada y salida de la guía, que conforman la cavidad resonante. La guía de onda angosta de índice de gradiente es obtenida por medio de una difusión primaria de cobre por fuente de estado sólido asistida por campo eléctrico y un proceso de difusión secundaria, la cual es por baño de sales o por medio de baño de sales asistido por un campo eléctrico externo. Se fabricaron diferentes guías de onda angostas y operan en el regimen monomodal y multimodal. A la entrada del transductor se acopla una fuente de luz láser y en la señal de salida se observan los efectos que se producen en el transductor debido a una variación de temperatura. La temperatura produce cambios, tanto en el índice efectivo de la guía de onda como en la longitud de la cavidad resonante que se forma con esta guía. Esto se traduce a cambios de intensidad en la señal de salida del transductor. Se obtuvieron resultados que nos permiten determinar el parámetro de cambio de temperatura de media onda (Tπ) de los diferentes
transductores analizados. This thesis comprises a theoretical and experimental study of an integrated optical temperature transducer type Fabry-Perot that operates in transmission mode. The transducer consist of a gradient index channel waveguides and two dielectrics mirrors on the input and output faces of the waveguide, they conform the resonant cavity. Channel waveguides were obtained by means of an ionic primary exchange process followed by a secondary diffusion process. The primary process is obtained by means of a difussion technique of Cu⁺ ions by a solid state technique. The secondary process is obtained by means of a salt melt bath or salt melt bath assisted by electric field. Several channel waveguides were manufactured and they operated in the regimen monomodal and multymodal. Laser light is coupled onto input face of the transducer and the light variations of output face were detected and attributed to the temperature changes induced in the transducer. The effective index of the waveguide and resonant cavity lenght are sensitive to the temperature variations. This variations are translated to changes of intensity in the output signal of the transducer. Tπ parameter, that is the halfwave temperature change was determined for several transducers analyzed. | |
CICESE | |
1999 | |
Tesis de maestría | |
Español | |
Angel Valenzuela, J. L.1999.Estudio de un transductor de temperatura de óptica integrada tipo Fabry-Perot.Tesis de Maestría en Ciencias. Centro de Investigación Científica y de Educación Superior de Ensenada, Baja California.97 pp. | |
ÓPTICA | |
Aparece en las colecciones: | Tesis - Óptica |
Cargar archivos:
Fichero | Tamaño | Formato | |
---|---|---|---|
13018.pdf | 22.67 MB | Adobe PDF | Visualizar/Abrir |