Por favor, use este identificador para citar o enlazar este ítem:
http://cicese.repositorioinstitucional.mx/jspui/handle/1007/2142
Técnica para medir el índice de refracción no lineal de un material con un solo pulso A single-shot technique for measurement of the nonlinear refractive index of materials | |
Alexandro Ruiz de la Cruz | |
MEHRDAD MOHEBI AFTAHI | |
Acceso Abierto | |
Atribución | |
Autoenfocamiento, índice de refracción no lineal, Transmitancia, Nonlinear refractive index, self focusing, single pulse | |
Se desarrollo una nueva técnica para medir el índice de refracción no lineal de un materialde un material que utiliza un solo pulso. Para esta técnica e proponen dos arreglos experimentales que basan su funcionamiento en la técnica conocida como z-scan. El primero de estos arreglos utiliza dos muestras no lineales, donde la función de una de ellas es la de hacer un barrido de la cintura del haz por la segunda muestra, haciendo uso del autoenfocamiento provocado por la intensidad del haz en la primer muestra. Obteniéndose un cambio en la transmitancia de una abertura colocada frente a la segunda muestra. También se desarrollo un programa para la simulación numérica de los resultados que se obtendrían en el laboratorio. Para esta simulación se utilizó teoría de propagación gausiana, de difracción y de óptica no lineal de tercer orden. En la simulación se observó muy buena sensibilidad por parte de los arreglos propuestos. En el laboratorio se implementó el arreglo que solo utiliza una muestra no lineal. Como muestra se utilizó una celda llena con CS2 cuyo índice de refracción no lineal es bien conocido en la literatura (n2=1.2E-11esu). Finalmente se muestran los resultados obtenidos en el laboratorio y el ajuste teórico obtenido para el valor correspondiente de n2 del material. Los resultados obtenidos mostraron estar en buen acuerdo con la teoría. A technique to measure the nonlinear refractive index of optical materials using a singlepulse was developed. Two different experimental setups were proposed for this technique. The first setup we proposed uses two nonlinear samples. The funtion of one of these samples is to scan the other nonlinear sample with the beam focus using the self-focusing of the beam in the fisrt sample. This self-focusing follows the input pulse intensity profile. We obtain a variation in the transmission f an aperture located in the far field in front of the second sample. The second setup only uses one nonlinear sample. Basically it is the same z-scan setup but we use fast detectors so that we can resolve the input pulse. The nonlinear sample is in a fixed position while the pulse profile causes the self-focusing condition in the sample to change with time. With this we obtain a time dependent variation in the transmission of the aperture or disc located in the far field in front of the detector. A numerical simulation of both setups was developed to compare theorethical and experimental results. Here we used gaussian propagation theory, diffraction theory and nonlinear optics theory. The setup with one nonlinear sample was implemented in the laboratory. The sample was a cell filled with CS2 wit a nonlinear refractive index n2=1.2E-11esu. Finally we show the results obtained in the laboratory and its theorethical fit with for different energies of the input pulse | |
CICESE | |
2000 | |
Tesis de maestría | |
Español | |
Ruiz de la Cruz, A.2000.Técnica para medir el índice de refracción no lineal de un material con un solo pulso.Tesis de Maestría en Ciencias. Centro de Investigación Científica y de Educación Superior de Ensenada, Baja California.93p. | |
ÓPTICA | |
Aparece en las colecciones: | Tesis - Óptica |
Cargar archivos:
Fichero | Tamaño | Formato | |
---|---|---|---|
136811.pdf | 17.85 MB | Adobe PDF | Visualizar/Abrir |