Por favor, use este identificador para citar o enlazar este ítem:
http://cicese.repositorioinstitucional.mx/jspui/handle/1007/2262
Polarización inducida con sondeos electromagnéticos transitorios sobre el pórfido cuprífero de El Arco, Baja California Induced polarization with transient electromagnetic soundings over the porphyry copper deposit of El Arco, Baja California | |
Sergio Alberto Peralta Ortega | |
Carlos Francisco Flores Luna | |
Acceso Abierto | |
Atribución | |
Sondeos Electromagnéticos Transitorios, Polarizacién inducida, Modelo Cole-Cole,Transient Electromagnetic Soundings, Induced Polarization, Cole-Cole model | |
El método geofisico de polarización inducida (PI) ha sido una herramienta muy util en el area de exploracién minera. Tradicionalmente, este método ha sido aplicado inyectando corriente al subsuelo y midiendo el voltaje resultante con un par de electrodos, en la mayoria de los casos con el arreglo electrddico dipolo-dipolo. En este trabajo se examinala viabilidad de realizar PI utilizando un método diferente, el de sondeos electromagnéticos transitorios (TDEM). El area de prueba es el yacimiento de cobre diseminado de E] Arco, Baja California. Los sondeos TDEM fueron realizados en las modalidades de bobina central y no central. Todos los sondeos de bobina central mostraron evidencia de subsuelos polarizables. Los datos de bobina central fueron invertidos a modelos uni-dimensionales (1-D) polarizables con un algoritmo linealizado de minimos cuadrados. El fenédmeno de PI fue incorporado en la inversidn al considerar que la resistividad en cada capa del modelo varia con la frecuencia de acuerdo con el modelo dispersivo Cole-Cole. Este modelo esta definido por cuatro parameitros en cada medio (resistividad DC, cargabilidad, constante de tiempo y exponente c). Los datos fueron invertidos a semiespacios homogéneos y modelos de dos capas, pero en la mayoria de estos ultimos la segunda capa resultó estar pobremente constrefida. Se demuestra que, a partir de los resultados obtenidos, es posible interpretar sondeos TDEM en términos de modelos Cole-Cole. Los valores de El Arco de cargabilidad contra constante de tiempo concuerdanconel diagrama de Pelton et al. (1978) y con las concentraciones de mineral medidas en barrenos. Estos resultados indican que es posible realizar discriminacién mineral con sondeos TDEM. Esta es la primera ocasiédn que se hace esto. Sin embargo, problemas de no-unicidad y de correlacién de parametros son limitantes en la aplicacién del método. Otralimitante para determinar la estructura eléctrica mas profunda fue la presencia de errores altos en los voltajes de los tiemposlargos. El intervalo explorado de profundidades fue de 100 a 500 m,lo cual sugiere que el yacimiento pudiera extenderse a profundidades mayores de 350 m. The geophysical method of induced polarization (IP) has been a very useful tool in the mining exploration area. This method traditionally has been applied by injecting current to the ground and measuring the resulting voltage with a pair of electrodes, mostly with the dipole-dipole electrode array. In this work the feasibility of doing IP with a different method, the transient electromagnetic soundings (TDEM) technique, is examined. The testing area is the disseminated copper deposit of El Arco, Baja California. The TDEM soundings were acquired with the central-loop and off-center arrays. All central-loop soundings showed evidence of polarizable grounds. Central-loop data were inverted to one-dimensional (1-D) polarized models with a linearized least-squares algorithm. The IP phenomenon wasincorporated in the inversion by considering, in each layer, a frequency-dependent resistivity following the Cole-Cole dispersion model. This model is defined by four parameters in each medium (DC resistivity, chargeability, time constant and exponent c). The data were inverted to homogeneous halfspaces and two-layer models, but in the latter the second layer was poorly constrained in most of the cases. The results indicate that TDEM soundings can beinterpreted in terms of Cole-Cole models. The El Arco values of chargeability against time constant agree with the mineral concentrations measured in drillholes and with the diagram proposed by Pelton et al. (1978). For thefirst time, these results indicate that it is possible to perform mineral discrimination with TDEM soundings. However, problems of non-uniqueness and parameter correlation limit the application of the method. Another limiting factor for determining the deep electrical structure is high uncertainties in the late-time voltages. The estimated depth range of exploration was from 100 to 500 m, suggesting that the deposit could extend to depths greater than 350 m. | |
CICESE | |
2001 | |
Tesis de maestría | |
Español | |
Peralta Ortega, S. A.2001.Polarización inducida con sondeos electromagnéticos transitorios sobre el pórfido cuprífero de El Arco, Baja California.Tesis de Maestría en Ciencias.Centro de Investigación Científica y de Educación Superior de Ensenada, Baja California.128 pp. | |
CIENCIAS DE LA TIERRA Y DEL ESPACIO | |
Aparece en las colecciones: | Tesis - Ciencias de la Tierra |
Cargar archivos:
Fichero | Tamaño | Formato | |
---|---|---|---|
142981.pdf | 5.35 MB | Adobe PDF | Visualizar/Abrir |