Por favor, use este identificador para citar o enlazar este ítem:
http://cicese.repositorioinstitucional.mx/jspui/handle/1007/4264
Inversión Conjunta 1D de datos de Sondeos Eléctricos Verticales y Transitorios Electromagnéticos Joint 1D Inversion of Vertical Electric and Transient Electromagnetic Sounding data | |
Gloria Hernández López | |
Carlos Francisco Flores Luna | |
Acceso Abierto | |
Atribución | |
Sondeo Eléctrico Vertical, Transitorio Electromagnético, resisitivad eléctrica, Inversión conjunta Vertical Electrical Sounding, Transient Electromagnetic, Electrical resisitivity, Joint Inversion | |
Los Sondeos Eléctricos Verticales (SEV) y los sondeos Transitorios Electromagnéticos (TEM) son técnicas frecuentemente usadas para estimar la resistividad eléctrica del subsuelo. En los SEVs se inyecta una corriente DC al terreno con dos electrodos de corriente y se mide la diferencia de potencial resultante con otro par de electrodos. En los sondeos TEM también se crea una corriente en el subsuelo, pero ésta se genera inductivamente al cortar la corriente en una espira de alambre aislado colocada sobre el terreno. La respuesta del subsuelo se registra con la variación temporal del voltaje inducido en una bobina de alambre situada cerca de la espira transmisora. Ambos métodos se usan para estimar la variación vertical de la resistividad (llamada uni-dimensional o 1D) en la vecindad de los sondeos, lo cual es usado en una amplia variedad de aplicaciones exploratorias. Puesto que la base física de estos métodos es diferentes, cada uno tiene sus ventajas y desventajas. El objetivo de realizar una inversión conjunta es que ellas se compensen y así aumentar la resolución de los parámetros de los modelos conjuntos. Por medio de la simulación numérica se analizaron las fortalezas y debilidades de estos dos métodos en profundidades someras, intermedias y altas. El programa de inversión conjunta se probó satisfactoriamente con datos sintéticos y con datos reales de la zona geotérmica de Las Tres Vírgenes, Baja California Sur. En ésta se corroboró la mejoría en las resoluciones de los parámetros de los modelos conjuntos respecto a los individuales, el efecto nocivo del ruido en ambos métodos, el efecto de heterogeneidades someras de la resistividad y la mayor sensibilidad a conductores del método TEM. Por otro lado, la aplicación de la inversión conjunta a pares de sondeos en la zona agrícola del Valle de Guaymas, Sonora no dio resultados satisfactorios, aparentemente por que los datos de los dos tipos de sondeos son contradictorios. Sin embargo, estas discrepancias se pueden explicar por un avance importante de la intrusión de agua marina en el lapso de 21 años entre las fechas en las que se adquirieron los dos tipos de sondeos. The Vertical Electrical Soundings (VES) and Transient Electromagnetic Soundings (TEM) are techniques frequently used to estimate the subsurface electrical resistivity. In VES, a DC current is injected to the ground with two current electrodes and the resulting potential difference is measured with another pair of electrodes. In TEM, a current is also created in the subsurface, but it’s generated inductively by cutting the current in an insulated wire coil laid on the ground. The subsurface response is recorded with the time variation of voltage induced in a wire loop near the transmitting loop. Both methods are used to estimate the vertical variation of resistivity (called one-dimensional or 1D) in the vicinity of the soundings, used by a wide variety of exploratory applications. As the underlying physics of these methods is different, each one has its advantages and disadvantages. The goal of a joint inversion is that they compensate each other resulting with a resolution improvement in the parameters of the joint model. With numerical simulation the strengths and weaknesses of the methods were analyzed in shallow, intermediate, and large depths. The joint inversion program was successfully tested with synthetic data and actual field data from the Las Tres Virgenes geothermal zone, Baja California Sur. In this zone the resolution improvement of the joint models was confirmed, the effect of noise in both methods, the effect of shallow resistivity heterogeneities, and the greater sensitivity to conductors of the TEM method. The joint inversion of several pairs of soundings in the agricultural Guaymas Valley, Sonora did not give good results, apparently because there are contradictions between the two types of data. However, these discrepancies can be explained by a significant advancement of the intrusion of sea water in the 21 years between the dates of acquisition of the two types of soundings. | |
CICESE | |
2025 | |
Tesis de maestría | |
Español | |
Hernández López, G. 2025. Inversión Conjunta 1D de datos de Sondeos Eléctricos Verticales y Transitorios Electromagnéticos. Tesis de Maestría en Ciencias. Centro de Investigación Científica y de Educación Superior de Ensenada, Baja California. 63 pp. | |
FLUJO DE CALOR (TERRESTRE) | |
Aparece en las colecciones: | Tesis - Ciencias de la Tierra |
Cargar archivos:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
tesis_Gloria Hernández López_2025.pdf | Descripción completa de la tesis | 4.96 MB | Adobe PDF | Visualizar/Abrir |