Simulación del flujo de agua subterránea en el acuífero del Valle de Guadalupe, Baja California, México Simulation of the groundwater flow in the aquifer of the Guadalupe Valley, Baja California, Mexico | |
JOSE RUBEN CAMPOS GAYTAN | |
THOMAS GUNTER KRETZSCHMAR STEINLE | |
Acceso Abierto | |
Atribución | |
Acuífero del Valle de Guadalupe,Modelo geohidrológico,Agua subterránea,Simulación numérica,Baja California | |
Se ha desarrollado un modelo del flujo de agua subterránea con el objeto de estudiar el comportamiento del nivel freático y evaluar distintas alternativas de manejo del agua subterránea a futuro en el Acuífero del Vall e de Guadalupe, en Baja California, México.
En la simulación del modelo geohidrológico del Acuífero del Valle de Guadalupe se utiliza un modelo del flujo de agua subterránea en dos dimensiones y la información proporcionada por la Comisión Nacional del Agua, la Comisión Estatal de Servicios Públicos de Ensenada, así como la generada por trabajos académicos y de investigación realizados en la zona de estudio, sobre las condiciones geohidrológicas que presenta el Acuífero del Valle de Guadalupe. Se modifica y mejora un simulador del flujo de agua subterránea desde el punto de vista numérico, al cual se le han integrado subrutinas para considerar los efectos generados por las variables de evapotranspiración y flujo de agua superficial (o drenes). La calibración del modelo numérico se ha llevado a cabo de manera conjunta para los estados estacionario y transitorio con el objeto de obtener el mejor ajuste posible entre el nivel freático calculado por el simulador con el registro del nivel freático medido en el Acuífero del Valle de Guadalupe. Con base en el análisis de la información disponible, se determina como fecha de inicio de la simulación el mes de febrero de 1984, y a partir de la misma, se calcula la evolución del acuífero por un período de 21 años, utilizando el intervalo de muestreo de un mes. Después de obtener los resultados del simulador, se reproducen las configuraciones de la superficie freática para las fechas que se cuenta con observaciones de campo, mayo de 1985, junio de 1988, abril de 1990, mayo de 1998, septiembre de 2001, marzo de 2003,
febrero de 2004, abril de 2004, junio de 2004, octubre de 2004 y abril de 2005. En general, la comparación de las configuraciones del nivel freático, observada y calculada, tienen buen ajuste cualitativa y cuantitativamente hablando. En particular, se calcula un indicador de ajuste entre los datos calculados por el simulador numérico y los datos medidos en campo para un número finito de pozos, cuyo resultado es satisfactorio, tomando en cuenta los objetivos del estudio. Además, en el período completo de simulación (1984-2007) se aprecia una tendencia clara del abatimiento del acuífero. La validación de los resultados del simulador se realiza mediante la comparación con los datos del nivel fr A groundwater flow model was developed in order to study the water table behavior and to evaluate several groundwater management alternatives in the Guadalupe Valley Aquifer, Baja California, Mexico. During the simulation of the geohydrological model of the Guadalupe Valley Aquifer is used a two-dimensional groundwater flow model and the information proportionate for the National Commission of Water, the State Public Services Commission of Ensenada, as well as the information generated by academic and research works carried out in the study zone, about the geohydrological conditions that present the Guadalupe Valle Aquifer. A groundwater flow simulator is modified and improved from the numerical point of view. Now, the groundwater flow simulator counts with subroutines to consider the effects of variables as evapotranspiration and surface water flow (or drains). Both steady-state and transient calibration were carried out in order to obtain the best possible match between the calculated and the measured water table elevation in the Guadalupe Valley Aquifer. Based on the analysis of the collected information, the beginning of the simulation period is February of 1984, and the evolution of the aquifer for a period of 21 years is calculated, using a sampling interval of one month. According to the simulator results, are reproduce the configurations of the phreatic surface for those periods with field observations. Among them are the phreatic surfaces of May 1985, June 1988, April 1990, May 1998, September 2001, March 2003, February 2004, April 2004, June 2004, October 2004 and April 2005. In general, the comparison of the phreatic surface configurations, observed and calculated, have a good adjustment qualitative and quantitatively speaking. In particular, is calculated an indicator of adjustment between the calculated data by the numerical simulator and the measured data in the field for a finite number of wells, whose result is satisfactory, according to the thesis objectives. In addition, in the whole simulation period (1984-2007) is appreciated a trend of the water table depletion in the aquifer. Validation of the simulator results is developed throughout the comparison with the measured water table elevation generated in the six sampling campaign (2004-2005) carried out as a complementary work of this thesis. Six groundwater management alternatives of the Guadalupe Valley Aquifer (2007-2025) were analyzed. Throughout the simulation of the groundwater ma | |
CICESE | |
2008 | |
Tesis de doctorado | |
Español | |
Campos Gaytán,J.R.2008.Simulación del flujo de agua subterránea en el acuífero del Valle de Guadalupe, Baja California, México.Tesis de Doctorado en Ciencias. Centro de Investigación Científica y de Educación Superior de Ensenada, Baja California.240 pp. | |
CIENCIAS DE LA TIERRA Y DEL ESPACIO | |