Por favor, use este identificador para citar o enlazar este ítem: http://cicese.repositorioinstitucional.mx/jspui/handle/1007/3275
Relación hidrogeoquímica e isotópica del acuífero superficial del Valle de Perote, Veracruz con el reservorio del campo geotérmico Los Humeros, Puebla
The hydrogeochemical and isotopic relationship of the shallow aquifer in Perote Valley, Veracruz with the reservoir of the Los Humeros geothermal field, Puebla
ABRAHAM MARTINEZ GONZALEZ
THOMAS GUNTER KRETZSCHMAR STEINLE
JOSE ENRIQUE INIGUEZ PACHECO
Acceso Abierto
Atribución
En el marco de la colaboración internacional entre México y la Unión Europea (Cooperación en investigación de energía geotérmica Europa-México para el desarrollo de Sistemas Geotérmicos Mejorados y Sistemas Geotérmicos Supercalientes) para el desarrollo de energía geotérmica, se llevaron a cabo diversas campañas de exploración hidrogeoquímica en las proximidades del campo geotérmico Los Humeros (Puebla). El modelo conceptual actual de este sistema geotérmico incluye una falla de tipo normal, externa a la caldera Los Humeros, llamada Falla Alchichica, localizada en el Valle de Perote (Veracruz). De algunos pozos agrícolas ubicados en este valle se extrae agua con altas concentraciones de boro y una temperatura superior a la temperatura media anual del aire, por lo tanto, se infirió que el acuífero somero es afectado por fluidos del reservorio geotérmico, que ascienden por la falla. Los mapas de temperatura y electro-conductividad permitieron relacionar un cambio de fase asociado a la Falla Alchichica, mientras que la composición de elementos mayores sugiere la existencia de por lo menos tres aguas subterráneas con distinta composición: la primera, es la recarga del acuífero que se origina en el Cofre de Perote; la segunda, es la descarga de fluidos geotérmicos; la tercera, es una mezcla entre los dos primeros. Debido a que el Valle de Perote es una región agrícola, el mapa de distribución de las concentraciones de nitratos señala sitios de contaminación antropogénica, probablemente por el uso de fertilizantes nitrogenados. Por otro lado, las altas concentraciones de magnesio sugieren que provienen de la interacción con rocas calizas de la Formación Orizaba, la cual puede ser la roca encajonante de un acuífero profundo. En el diagrama de clasificación de Piper se identifican dos grupos de muestras: bicarbonatadas cálcicas-magnésicas y bicarbonatadas sódicas. El análisis de componentes principales determinó que las aguas subterráneas del acuífero somero están afectadas por procesos de intercambio iónico, precipitación y/o alteración de minerales. Finalmente, con el análisis de componentes principales se determinó que las muestras tomadas en el bloque NW de la Falla Alchichica muestran influencia de la descarga de fluidos hidrotermales procedentes del reservorio del campo geotérmico Los Humeros, lo cual se confirmó con las relaciones isotópicas δ O, 18 δD, δ B. 11 B.
In the framework of the international collaboration between Mexico and the European Union (Cooperation in Europe-Mexico geothermal energy research for the development of Improved Geothermal Systems and Superhot Geothermal Systems) for the development of geothermal energy, various exploration campaigns were carried out hydrogeochemistry near Los Humeros geothermal field (Puebla). The current conceptual model of this geothermal system includes a normal fault, the Alchichica Fault, external to Los Humeros caldera, located at the Perote Valley (Veracruz). Water extracted from agricultural wells located at the valley has high concentrations of boron and temperature higher than the annual average air-temperature; therefore, we inferred that the shallow aquifer is affected by geothermal fluids, which rise through the fault. The temperature and electro-conductivity maps allowed to relate a phase change to the Alchichica Fault, the major elements maps suggest at least three types of groundwaters with different composition: the first is the recharge of the aquifer that originates in Cofre de Perote; the second is the discharge of geothermal fluids; the third is a mix between the first two. Because of the Perote Valley is an agricultural region, the distribution map of nitrate concentrations indicates anthropogenic contamination at some sites, probably due to the use of nitrogenous fertilizers. On the other hand, the high concentrations of magnesium suggest that they originated from the interaction with limestone rocks of the Orizaba Formation, which can be the hosting rock of a deep aquifer. Two groups of samples were identified in Piper's classification diagram: calcium-magnesium bicarbonates and sodium bicarbonates. The principal component analysis determined that the groundwater of the shallow aquifer is affected by ion exchange processes, precipitation, or alteration of minerals, or both. Finally, with the analysis of principal components, it was determined that water samples collected on the NW block from Alchichica Fault shown the influence of the discharge of hydrothermal fluids from the reservoir of the Los Humeros geothermal field, which was confirmed with the isotopic ratios δ O, 18 δD, δ B 11 B.
CICESE
CICESE
2020
Tesis de maestría
Español
Martínez González, A. 2020. Relación hidrogeoquímica e isotópica del acuífero superficial del Valle de Perote, Veracruz con el reservorio del campo geotérmico Los Humeros, Puebla. Tesis de Maestría en Ciencias. Centro de Investigación Científica y de Educación Superior de Ensenada, Baja California. 111 pp.
OTRAS
Aparece en las colecciones: Tesis - Ciencias de la Tierra

Cargar archivos:


Fichero Descripción Tamaño Formato  
Tesis_Abraham Martínez González.pdfVersión completa de la tesis19.12 MBAdobe PDFVisualizar/Abrir