Por favor, use este identificador para citar o enlazar este ítem:
http://cicese.repositorioinstitucional.mx/jspui/handle/1007/548
Estudio de la birrefringencia de una fibra monomodo con núcleo líquido quiral Study of birefringence of an optical fiber with chiral liquid core | |
Marco Antonio Arce del Hoyo | |
Diana Tentori Santacruz | |
Acceso Abierto | |
Atribución | |
Tubo capilar, fibra monomodo, luz infraroja | |
El alto grado de estereoselectividad de muchos procesos biológicos conduce a que la actividad biológica, la toxicidad, la distribución y el metabolismo de un fármaco dependan en gran medida de su estereoquímica la cual se evalúa a partir de su actividad óptica. Hay muchos ejemplos que muestran cómo un enantiómero presenta actividad química asociada a una actividad óptica izquierda o derecha, mientras que el otro estereoisómero que presenta el giro opuesto no tiene efecto farmacológico; o bien, uno es tóxico frente al otro que demuestra ser seguro y activo. En el presente trabajo se ha desarrollado la metodología para rellenar un tubo capilar con un líquido quiral de forma tal que el conjunto funciona como una fibra monomodo. Se trabajó en el infrarrojo (1480 a 1570 nm) por lo que fue necesario evaluar la quiralidad del (R)-Limonene y (S)-Linalool (muestras quirales seleccionadas a partir de la literatura) usando una cubeta óptica y la metodología tradicional (polarímetro) y se verificó la calidad de estas medidas utilizando un líquido isótropo. Se implementó un arreglo polarimétrico empleando una fibra de núcleo líquido para evaluar la birrefringencia de las muestras quirales e isótropa. El uso de un contenedor capilar permitiría usar cantidades muy pequeñas de la muestra ópticamente activa para evaluar su quiralidad. Sin embargo una fibra de núcleo líquido funciona como un despolarizador. Las fluctuaciones térmicas y el tiempo de promediación (~ms) de nuestro detector no permitieron obtener resultados precisos de la actividad óptica. The high degree of stereoslectivity of many biologic process that lead to biological activity, toxicity, the distribution and the metabolism of a medicament, depend to a great extent on the stereochemistry which is evaluated from its optical activity. There are many examples showing how one enantiomer exhibits chemical activity associated with a left or right optical activity, while the other having the opposite rotation has no pharmacological effect; either one is toxic against the other which proves to be safe and active. In this paper the methodology to fill a capillary tube with a chiral liquid so that the set functions as a single-mode fiber was developed. We worked in the infrared (1480-1570 nm) so it was necessary to evaluate the chirality of (R)-Limonene and (S)-Linalool (chiral samples selected from literature) through an optical cuvette, using the traditional way to do it (using a polarimeter) and the quality of these measurements was verified using an isotropic liquid. In addition, we implemented a polarimetric arrangement using liquid core fibers for evaluating the birefringence of chiral and isotropic samples. This allows using very small amounts of the optically active sample to evaluate its chirality. Nevertheless, a liquid fiber core functions as a polarization scrambler. Thermal fluctuations and the averaging time of our detector (~ms) did not allow reaching accurate results of the optical activity for small volumes of the liquid samples. | |
CICESE | |
2014 | |
Tesis de maestría | |
Español | |
Arce del Hoyo, M.A.2014.Estudio de la birrefringencia de una fibra monomodo con núcleo líquido quiral.Tesis de Maestría en Ciencias. Centro de Investigación Científica y de Educación Superior de Ensenada, Baja California.69 pp | |
ÓPTICA | |
Aparece en las colecciones: | Tesis - Óptica |
Cargar archivos:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
237571.pdf | Versión completa de la tesis | 2.46 MB | Adobe PDF | Visualizar/Abrir |